Seismic performance evaluation of RBS-CFT connections with bidirectional bolts under cyclic loads

dc.contributor.authorPaul, Subhra
dc.date.accessioned2023-12-20T10:28:26Z
dc.date.available2023-12-20T10:28:26Z
dc.date.issued2022
dc.descriptionSupervisor: Deb, Sajal K
dc.description.abstractThis thesis presents experimental investigation on evaluation of performance of a new type of steel reduced beam section (RBS), designated as V-cut, and on its role in improving overall safety of RBS-CFT connections subjected to cyclic load. Detailed design steps adopted for design of the V-cut RBS with lower depth of cut, as compared to that in the conventional radius cut RBS, are reported in this paper. Behavior of four types of steel RBS and concrete filled tube (CFT) connections with bidirectional bolts were examined. An experimental study was performed to compare the performance of V-cut RBS with that of the other conventional radius cut RBS under cyclic loading. It exhibited improved hysteretic behavior, and the new RBS-CFT connection is found to be semi-rigid in nature. Test results show that the energy dissipation in the composite steel connections with V-cut RBS is higher than that with radius cut RBS. The application of V-cut steel flange beam effectively enhanced ductility and reduced the residual torsional deformation. It reached a rotational capacity of 0.04 radians without any damage in the joint panel region, and thereby meets the seismic provisions of the AISC as a special composite moment-resisting frame. Detailed and simplified nonlinear finite element analysis of RBS-CFT connections with bidirectional bolts was performed using the general-purpose software ABAQUS and OpenSees respectively. The failure patterns of the connections were obtained by the ABAQUS software. Simplified model was proposed in OpenSees to regenerate the hysteresis loops as obtained from the experimental study. Finally, seismic vulnerability assessment has been done by developing experimental fragility curves.
dc.identifier.otherROLL NO.166104029
dc.identifier.urihttps://gyan.iitg.ac.in/handle/123456789/2493
dc.language.isoen
dc.relation.ispartofseriesTH-2899
dc.subjectBidirectional Boltsen_Us
dc.subjectCFTen_US
dc.subjectRBSen_US
dc.subjectSemi-grid Connectionen_Us
dc.subjectSpecial MRFsen_US
dc.titleSeismic performance evaluation of RBS-CFT connections with bidirectional bolts under cyclic loads
dc.typeThesis
Files
Original bundle
Now showing 1 - 2 of 2
No Thumbnail Available
Name:
Abstract-TH-2899_166104029.pdf
Size:
106.84 KB
Format:
Adobe Portable Document Format
Description:
ABSTRACT
No Thumbnail Available
Name:
TH-2899_166104029.pdf
Size:
13.27 MB
Format:
Adobe Portable Document Format
Description:
THESIS
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: